Ignition; Start-Up Phase; Failed Ignition; Standard Operation - ZANTIA VOLUSA Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Instructions for use
fig. 23 control panel - stove status display
4.11

IGNITION

To switch the product on, press the key (1) for a few seconds.
The display shows when the snow has started (see fig. 24)
fig. 24 control panel - ignition
4.12

START-UP PHASE

The product performs the start-up phases in sequence as de-
fined by the parameters managing levels and times.
4.13

FAILED IGNITION

When a time preset by the manufacturer has elapsed and the
flue gas temperature has not reached the minimum value,
also preset by the manufacturer, the product goes into alarm
status (see table 7 problems/causes/remedies in chap. 7.3).
4.14

STANDARD OPERATION

Upon successfully completing the start-up phase, the stove
switches to the "operating" mode that represents standard op-
eration. If the flue gas temperature exceeds a value preset by
the manufacturer, the heat exchangers are enabled, fig. 25.
Heat exchangers 2 and 3 are only activated if they are en-
abled.
fig. 25 control panel - operating condition
4.15
CHANGING THE ROOM TEMPERATURE
SETTING
To change the room temperature, just act on the keys (1) and
(2). The display shows the current status of the temperature
setting, fig. 26.
1
2
fig. 26 control panel - room temperature modification
4.16
USING THE EXTERNAL THERMOSTAT/
CHRONOTHERMOSTAT
It is possible to connect an external thermostat to the stove
for remote management of some functions.
external thermostat: set a temperature of 7°C.
external chronothermostat: set temperature of 7°C and
Volusa rev.00
from the menu "03 Set chrono -> 01 enable chrono" disable
the chrono function (off).
The stove is enabled when it is on and the contact
is closed. The external thermostat must be con-
nected by the Authorised Assistance Centre.
1
4.17
ROOM TEMPERATURE REACHES THE SET
TEMPERATURE
When the room temperature or the flue gas temperature have
reached the set value, the heat output is automatically
brought to the minimum value "MODULATION" condition, see
fig. 27.
fig. 27 control panel - set temperature modulation
If STANDBY mode is activated, the stove switches off with a
delay equal to the time preset by the manufacturer after hav-
ing reached the set temperature.
The stove restarts after the room temperature
drops below the set temperature for an amount
of time preset by the manufacturer.T
4.18

CLEANING THE BRAZIER

During standard operating conditions, the "BRAZIER CLEAN-
ING" mode is activated at intervals established by the manu-
facturer for a preset amount of time.
fig. 28 control panel - brazier cleaning mode
4.19

SWITCH-OFF

To switch the stove off, just press the button (4) for about 2
seconds. The auger stops immediately and the flue gas extrac-
tor is brought to high speed. "FINAL CLEANING" is carried out.
When the flue gas temperature has dropped to a value set by
the manufacturer, the flue gas extractor is disabled after a pre-
set amount of time.
fig. 29 control panel - final cleaning
translated from the original text
< T
.
room
set
EN
4
19