INITIAL LOAD

Perform the operation below when the pellet
loading pipe is empty.
This allows you to perform a pellet preload lasting 90" with
the stove off and cold. Start by pressing the key (1) and inter-
rupt by pressing the key (4). The following also appear on the
display: Timer (A), Power (B), Room Temp. (C).
fig. 25 control panel - initial pellet loading
1
4.10

BOILER STATUS

Displays the instantaneous status of the boiler by showing
the status of the various devices connected to it. Various pag-
es are available and displayed in sequence. The following also
appear on the display: Timer 1 (A), Time-out (B), Status (C),
Alarm delay (D), Operating status (E), Flue gas Temp. (F), Flue
gas Flue gas extraction (G), Instant power (I), Alarm in pro-
gress (N).
C
EN
fig. 26 control panel - stove status display
4.11

IGNITION

To switch the product on, press the key (1) for a few seconds.
The display shows when the snow has started (see fig. 28)
fig. 27 control panel - ignition
46
C
B
A
A
D
B
E
G
I
F
N
translated from the original text
4.12

START-UP PHASE

The product performs the start-up phases in sequence as de-
fined by the parameters managing levels and times.
4.13

FAILED IGNITION

When a time preset by the manufacturer has elapsed and the
flue gas temperature has not reached the minimum value,
also preset by the manufacturer, the product goes into alarm
status (see table 7 problems/causes/remedies in chap. 7.3).
4.14

STANDARD OPERATION

Upon successfully completing the start-up phase, the stove
switches to the "operating" mode that represents standard op-
eration.
fig. 28 control panel - operating condition
4.15
CHANGING THE ROOM TEMPERATURE
SETTING
To change the room temperature, just act on the keys (1) and
(2). The display shows the current status of the temperature
setting, fig. 29.
1
2
fig. 29 control panel - room temperature change
4.16
USING THE EXTERNAL THERMOSTAT/
CHRONOTHERMOSTAT
It is possible to connect an external thermostat to the boiler
for remote management of some functions.
external thermostat: set a temperature of 7°C.
external chronothermostat: set temperature of 7°C and
from the menu "03 Set chrono -> 01 enable chrono" disable
the chrono function (off).
The stove is enabled when it is on and the contact
is closed. The external thermostat must be con-
nected by the Authorised Assistance Centre.
1
Instructions for use
Mod. KERA rev 01