Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
01111111 7F
Function call
ADDRESS
00010100 14
link
0010ffff 2f
number High
0mmmmmmm mh
number Low
0mmmmmmm ml
inpatch
DATA
0iiiiiii ih
0iiiiiii il
outpatch
0ooooooo oh
0ooooooo ol
End of exclusive
EOX
11110111 F7
function
SCENE LIB LINK
13.4.25 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches
the device number included in the SUB STATUS. This is echoed if [Param-
eter change ECHO] is ON.
When this is received, a Parameter Change message will be transmitted on
the [Rx CH].
Refer to the above table for the Functions and Numbers.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
Universal
MODEL ID
01111111 7F
Function call
ADDRESS
00010100 14
link
0010ffff 2f
number High
0mmmmmmm mh
number Low
0mmmmmmm ml
End of exclusive
EOX
11110111 F7
13.4.26 Parameter change
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the same processing that is executed when the key
specified by Address is pressed (released).
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Key remote
ADDRESS
00100000 20
Key address H
0kkkkkkk kk
Key address M
0kkkkkkk kk
Key address L
0kkkkkkk kk
Release:0, Press:1
DATA
0ppppppp pp
End of exclusive
EOX
11110111 F7
13.4.27 Parameter change
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds.
When you want to transmit meter information continuously, a Request
must be transmitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified
by Address will be transmitted on the [Rx CH] channel at 50 msec intervals
for a duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if
number
0x20
0-99 (0:response only)
(Function call: link)
(Key remote)
(Remote meter)
Format Details
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Remote meter
ADDRESS
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
data1 H
DATA
0ddddddd dd
Data1 L
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
13.4.28 Parameter request
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, data of the specified address is transmitted on the
[Rx CH] at intervals of 50 msec as a rule, for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Remote meter
ADDRESS
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
mmmmmmm
mm
Count H
0ccccccc ch
Count L
0ccccccc cl
End of exclusive
EOX
11110111 F7
13.4.29 Parameter change (Remote time counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
02R96
MODEL ID
00001011 0B
Remote Time counter
ADDRESS
00100010 22
0:Time code, 1:Measure.Beat.Clock
0000tttt 0t
Hour / Measure H
0ddddddd dd
Minute / Measure L
0ddddddd dd
Second / Beat
DATA
0ddddddd dd
Frame / Clock
0ddddddd dd
End of exclusive
EOX
11110111 F7
02R96 Version 2—Mode d'emploi