Beninca brain Livret D'instructions page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
MENU
Select the 1/2 motors operating mode:
On: only one motor (motor 1) active. Function to be used in the following cases:
- for single motor, to connect M1:4-5-6.
1mot
- for two syncronized motors (for instance overhead door), to connect M1:4-5-6
and M2:7-8-9. You need to regulate the parameters related to the motor 1,
the limit switch entries M2 are disarmed (not activate).
Off: Both motors operating.
The calculation of residual operating time is activated or deactivated in the
event of partial operations:
On: Calculation of deactivated time. In case of partial operations, the opera-
ting time is reset. The following operation restarts for the entire time preset by
not
parameter TM1/TM2.
Off: Calculation of activated time. In case of partial operations, the operating
time is stored in memory and then subtracted from the TM1/TM2 parameter
value in the following operation.
The thrust function in the closing phase is activated or deactivated by this logic.
With SLD logic only: ON
On: the operation in the closing phase is carried out at normal speed during the
bb
last second (braking is disabled). In this way, a better hooking of the electric
lock is performed.
Off: disabled function.
MENU
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
RES
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button
again resets the control unit.
Displays the number of complete cycles (open+close) carried out by the automation.
NMAN
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the
last 4. Example <PG> 0012 >>> <PG> 3456: made 123.456 cycles.
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s
- activate pre-blinking
Perform the operations described below step by step:
Step
Press
Display
1
2
3
4
5
6
7
8
9
10
11
12
EXAMPLE OF PROGRAMMING
PAR
First menu
TCA
First function of the first menu
040
Value currently set for the function selected
100
Set the desired value with the <+> and <-> keys
PRG
The value is programmed
TCA
When programming has been made, the display goes to the function just set
PAR
Press <+> and <-> simultaneously to go to the higher menu
Log
Second menu
TCA
First function of the second menu
Pre
Press <-> several times to select PRE logic
OFF
Value currently set for the function selected
ON
Set the desired value with the <+> and <-> keys
FUNCTION
FUNCTION
Settable values
ON-OFF-(Default)
Notes
MEMO
(OFF)
(ON)
(OFF)

Publicité

Table des Matières
loading

Table des Matières