Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2SHUDWLQJ LQVWUXFWLRQV
(96
'6 ,8 DQG (96

Technical data

Power supply
Alternating voltage 230 V / 50 Hz, single phase
Range approx. 195 V - 250 V / 50 – 60 Hz.
Output current:
Charging current EVS 30/20-DS/IU max. 20 A,
(Charging current for
Charging current EVS 30/30-DS/IU max. 30 A,
battery II)
arithmetic average, electronically controlled according to
the charging characteristic curve ,8R8.
Output current:
When the battery potential of battery II reaches 14.3 V, a
(Charging current for
parallel connection is established with battery I.
battery I)
Compensating current dependent on the charge state of
battery I (starter battery). If the voltage of the battery II
drops below 13.2 V, the parallel circuit is automatically
disconnected.
Output voltage:
Direct voltage 12 V
Charging process:
Automatic
Automatic
OFF when battery voltage reached 14.4 V
switching:
EVS 30/20-DS/IU charging current < 18 A,
(Main charging phase)
EVS 30/30-DS/IU charging current < 27 A.
Automatic
Ten hours constant 14.4 V in the case of gel batteries.
switching:
Four hours constant 14.4 V in the case of liquid
(Post charging phase)
batteries.
Automatic
Holding charge, constant at 13.8 V.
switching:
(Holding charge phase)
Switching
Tremat isolating relay 50A
capacity:
Refrigerator relay 20A
User relay 3A
7UDXWPDQQ *PE+
&R .* &$/,5$
8
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: 08341 / 9764-0 Fax: 08341 / 67806
'6 ,8
&$/,5$ $SSDUDWHEDX
&$/,5$
&$/,5$

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Evs 30/30-ds/iu

Table des Matières