Changeover switch battery type
When the device is delivered, it is set to operation with liquid
electrolyte batteries. If necessary, set the battery type (liquid or gel)
of your battery II at the changeover switch (fig. 10).
)LJ

Mains connection

Connect the mains cable to the power distribution of your
boat, mobile home or caravan. Connect the green/yellow
cable to the earth circuit! Check that all the connections are
firm and secure. Finally make the mains connection with the
female device plug (fig. 11) of the mains cable.
)LJ

Commissioning

The power supply is operational as soon as it is connected to the mains.
Before breaking or making direct-current connections, e.g. the charging cable
at the battery, the device be switched off at the mains. Pull out the mains plug.
1HYHU FKDUJH EDWWHULHV ZLWK VKRUW FLUFXLWHG FHOOV
Charging a battery
Explosive gases (oxyhydrogen) are produced if charging is carried out with a
short-circuited battery, or when the power supply is non-operational. Therefore
it is necessary to ensure sufficient external ventilation in the battery space.
Avoid sparks and open flames!
Prerequisites
The battery must have a rated voltage of 12 volt and a minimum capacity of 70
Ah when using the EVS 30/20 DS/IU or 100 Ah when using the EVS 30/30
DS/IU. Insufficient charging takes place if the battery is below this value.
Batteries with a capacity that is too high are charged too slowly.
Attention
Batteries with short-circuited cells must not be charged. Explosion hazard due
to the generation of oxyhydrogen gas!