Cable lengths and cross-sections

Positive
Length up to 3 m
charging cable
Cable cross
red
section: 6 mm².
Negative
Length up to 3 m
charging cable
Cable cross
blue
section: 6 mm².
Measuring cable B+ red
For length of up to 10 m, cable cross-section
0.75 mm².
Cable D+ brown
For length of up to 10 m, cable cross-section
0.75 mm².
Function display
At least 0.25 mm²
12 V user
At least 2.5 mm²
Refrigerator
At least 2.5 mm²
Battery II test
At least 0.25 mm²
Negative test
At least 0.25 mm²
Negative
At least 2.5 mm²
Permanent positive for
At least 2.5 mm²
refrigerator
Permanent positive
At least 2.5 mm²
Signal from Tremat
At least 0.25 mm²
Trigger user relay
At least 0.25 mm²
Battery I test
At least 0.25 mm²
7UDXWPDQQ *PE+
&R .* &$/,5$
12
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: 08341 / 9764-0 Fax: 08341 / 67806
'6 ,8
Length up to 6 m
Length over 6
Cable cross
m,
section: 10 mm².
Cable cross
section: 16
mm².
Length up to 6 m
Length over 6
Cable cross
m,
section: 10 mm².
Cable cross
section: 16
mm².