Technical Data - Calira EVS 17/16-DS/IU Mode D'emploi

Masquer les pouces Voir aussi pour EVS 17/16-DS/IU:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

-
$% ./ ./#)% *+

Technical data

Power supply
Alternating voltage 230 V / 50 Hz, single-phase
Range approx. 180 V - 264 V / 50 – 60 Hz.
Output current:
Max .charging current 16 A, electronically regulated
(Battery 2 charging current)
according to the charging characteristic curve
Output current:
When the battery potential of battery 2 reaches 14,1 V, a
(Battery 1 charging current)
parallel connection is established with battery 1. Com-
pensating current dependent on the charge state of battery
1 (starter battery). If the voltage of the battery 2 drops
below 13.0 V, the parallel circuit is automatically discon-
nected.
Output voltage:
Direct voltage 12 V
Charging process:
Automatic
Automatic switching:
OFF when battery voltage reaches 14.4 V, charging cur-
(Main charging process)
rent < 16 A.
Automatic switch-
Ten hours constant 14.4 V in the case of AGM / gel bat-
ing:
teries.
(Post charging phase)
Four hours constant 14.4 V in the case of liquid batteries.
Automatic switch-
Holding charge, constant at 13.8 V.
ing:
(Holding charge)
Temperature de-
The values of the automatic switching refer to a battery
pendent control
temperature of 20° C. When using a temperature sensor at
(optional)
the battery 2, these values vary as a function of the bat-
tery temperature.
High temperature - lowering of the threshold values.
Low temperature - higher threshold values.
Application:
Parallel operation, buffer operation, general charging
operation
Temperature:
Ambient temperature of -25° C to +35° C.
During operation, the device housing may heat up to
approx. 75 °C.
Cooling:
By convection
! "
Lerchenfeldstr. 9 87600 Kaufbeuren Tél. : +49(0)8341 / 9764-0 Fax : +49(0)8341 / 67806
.
#