CPV..-GE-ASI-...
5

Technical specifications

Type
Protection class (as per DIN 40050)
Temperature
• during operation
• during storage/transport
Electromagnetic compatibility
• Interference radiated
• Resistance to interference
ASI bus connection
• Voltage range (protected against
incorrect polarity)
• Residual ripple
• Max. current consumption at -5
(all valves on)
a) Type CPV..-GE-ASI-2/4
- with current reduction
b) Type CPV..-GE-ASI-...-Z
Load voltage connection
only with type CPV..-GE-ASI-...-Z
• Rated value
(protected against incorrect polarity)
• Residual ripple
• maximum starting current (at 24 V)
• Starting current for 4 valves with
current reduction
ASI data (parameter outputs have
no use)
• ID CODE
• IO CODE
• Profile
9708A
CPV..-GE-ASI-...
IP 65 (compl. fitted)
o
- 5
... + 50
o
- 20
... + 70
• tested as per EN 55011,
limit class B
• tested as per EN 50082-2
DC 26.5 V...31.6 V
≤ 20 mVpp
o
C
CPV10
140 mA
73 mA
25 mA
DC 24 V + 10%/-15%
(DC 20.4 V...26.4 V)
4 Vpp
CPV10
108 mA
48 mA
FH
8H
S-8.F
o
C
o
C
CPV14
CPV18
208 mA
352 mA
97 mA
145 mA
25 mA
25 mA
CPV14
CPV18
176 mA
320 mA
72 mA
120 mA