Ismatec MCP-CPF Mode D'emploi page 38

Classe de protection ip 65
Table des Matières

Publicité

Hinweis
In Abhängigkeit der Betriebstemperatur
können Analog-Eingänge und -Ausgänge
eine geringe Drift aufweisen. Für höchste
Ansprüche in Bezug auf Drehzahlvorgabe
und -konstanz empfehlen wir daher die
Ansteuerung via RS232-Schnittstelle. Für
die Drehzahlüberwachung mittels Ausgang
‚speed OUT' empfehlen wir die Einstellung
‚Frequenz' zu verwenden.
Please note
Depending on the operating temperature,
analog inputs and outputs may have a slight
drift. If highest performance is required
with respect to speed setting and speed
constancy, we recommend to control the
pump via the RS232 interface. For monitoring
the speed via the output "speed OUT" we
suggest using the "frequency mode".
Remarque
Les entrées et sorties analogiques peuvent
montrer une certaine dérive en fonction de
la température de fonctionnement. Lorsque
les performances les plus hautes sont exigées
en rapport au réglage et à la constance de
la vitesse, nous recommandons de contrôler
la pompe par son interface sérielle RS232.
Pour contrôler la vitesse par la sortie "speed
OUT", nous recommandons d'utiliser le mode
"fréquence".
MCP-CPF PROCESS, 14-017, REV. C
Analogschnittstelle
Pin 9, speed OUT
Die werkseitige Einstellung ist 0 – 10
V
, proportional zur Motordrehzahl.
DC
Alternativ steht ein Frequenzbereich
von 0/7.2 kHz zur Verfügung.
Wahlmöglichkeit mittels Schiebeschalter
S2 im Geräteinnern (siehe Seite 39).
Pin 10, +5 V
DC
Es stehen ca. +5 V
zur Verfügung.
DC
(max. Strom 0.5 A)
Pin 13, speed intern
Abhängig von der Betriebsart hat
Pin 13 unterschiedliche Funktionen:
Analogschnittstelle nicht aktiviert
(Normalbetrieb, d.h. Pin 2 offen)
Hier dient Pin 13 als Autostart-
funktion. Ist Pin 13 mit Pin 1 (GND)
verbunden, kann die Pumpe direkt
über die Netzspannung gestartet bzw.
angehalten werden (Netzschalter muss
eingeschaltet sein).
Analogschnittstelle aktiviert
(Pin 2 auf GND)
X
X
Pin 13 offen: Die Drehzahl wird über
Pin 5 (speed IN) vorgegeben.
X
X
Pin 13 auf GND Die Drehzahl kann
am Bedienungspanel der Pumpe
eingestellt werden.
Pin 14, output 1 (PWM)
Pin 15, output 2 (PWM)
Digitale Ausgänge in Verbindung
mit Pin 7 (+26 VDC), als Pulsweiten-
Modulation ausgeführt (Open
Collector). Können nur über RS232-
Schnittstelle aktiviert werden; z.B. mit
einer Software wie ProgEdit.
Analog interface
Pin 9, speed OUT
The default setting is 0 – 10 V
,
DC
proportionally to the motor speed.
Alternatively a frequency range from
0/7.2 kHz is available. Alternatives with
sliding switch S2 inside the pump (see
Page 39).
Pin 10, +5 V
DC
About +5 V
are available.
DC
(max. current 0.5 A)
Pin 13, speed intern
Depending on how the pump is
operated, pin 13 has different functions:
Analog interface not activated (Normal
operation, i.e. pin 2 is open) Pin 13
serves as auto-start function. If pin 13
is connected to pin 1 (GND), the pump
can be started and stopped directly
from the power supply (the power
switch must be ON).
Analog interface activated
(Pin 2 on GND)
X
X
Pin 13 open: The rotation speed is
adjusted via pin 5 (speed IN).
X
X
Pin 13 on GND: The rotation speed
can be adjusted by the speed selector
on the control panel of the pump.
Pin 14, output 1 (PWM)
Pin 15, output 2 (PWM)
Digital outputs in connection with pin 7
), implemen-ted as pulse-width-
(+26 V
DC
modulation (open collector). Can only
be activated via RS232 interface; e.g.
with a software like the ProgEdit.
Interface analogique
Pin 9, speed OUT
Le réglage d'usine par défaut est 0 – 10
V
, proportionnel au nombre de tours
DC
du moteur.
Une zone de fréquence de 0/7.2 kHz
est à disposition en alternative.
Possibilité de sélection au moyen
d'un interrupteur coulissant S2 à
l'intérieur de l'appareil (v.p. 39).
Pin 10, +5 V
CC
Environ +5 V
sont à disposition
CC
(courant maximal 0.5 A)
Pin 13, speed intern
Le pin 13 possède des fonctions
différentes en fonction du mode
d'opération:
Interface analogique non activée (Mode
d'opération normal, c.-à-d. pin 2 ouvert)
Le pin 13 a la fonction „auto-start". Si
le pin 13 est connecté au pin 1 (GND), la
pompe peut être mise en route ou
arrêtée directement par l'alimentation
électrique (l'interrupteur principal doit
être sur ON).
Interface analogique activée
(Pin 2 sur GND)
X
X
Pin 13 ouvert: La vitesse de rotation
doit être ajustée par le pin 5 (speed IN).
X
X
Pin 13 sur GND: La vitesse de
rotation peut être ajustée par le
sélecteur de vitesse sur le tableau
de commande de la pompe.
Pin 14, output 1 (MLI)
Pin 15, output 2 (MLI)
Sorties numériques en relation avec le
pin 7 (+26 V
), mis en œuvre comme
CC
modulation de largeur d'impulsion
(collecteur ouvert). Ne peuvent être
activées que par l'interface RS232, p.e.
avec le logiciel ProgEdit.
38 of 65

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ism 919

Table des Matières