ADJUSTING THE STAPLING DEPTH

WARNING
When adjusting the Adjuster, be sure to
remove your finger from the trigger and
disconnect the air hose from the stapler.
To assure that each staple penetrates to the same depth,
be sure that:
1)
the air pressure to the Stapler remains constant
(regulator is installed and working properly), and
2)
the Stapler is always held firmly against the
workpiece.
If staples are driven too deep or shallow into the
workpiece, adjust the stapling in the following order.
1 DISCONNECT AIR HOSE FROM STAPLER.
Adjuster
2 If staples are driven too deep, turn the adjuster to
the shallow side.
If staples are driven too shallow, turn the adjuster
to the deep side.
Turn Adjuster
Too Deep
Turn Adjuster
Too Shallow
1 5
Disconnect
air hose
Flush
Flush
3 Stop turning the adjuster when a suitable position
is reached for a stapling test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a stapling test.
5 DISCONNECT AIR HOSE FROM STAPLER.
6 Choose a suitable position for the adjuster.
NOTE:
The staple might not drive deep enough if using
high pressure with the adjuster set upwards
(shallow side) due to factors such as the material
hardness or staple type.
If that happens, reduce pressure and set the
adjuster to lowest position so the staple drives in
at a good position.

CHANGING THE EXHAUST DIRECTION

WARNING
When changing the exhaust direction,
be sure to remove your finger from the
trigger and disconnect the air hose from
the stapler.
The direction of the exhaust vent can be changed by
turning the top cover.
Exhaust
vent

USING THE NOSE CAP

WARNING
When detaching or attaching the nose
cap, be sure to remove your finger from
the trigger and disconnect the air hose
from the stapler.
The nose cap is attached to the push lever tip to protect
the workpiece from scratches or damage. Remove in
the order shown below when not using.
1 DISCONNECT AIR HOSE FROM STAPLER.
2 Pull out the nose cap in the direction of the arrow
as shown in the diagram.