hestan Aspire Serie Manuel D'utilisation Et D'entretien page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
ERROR DISPLAY
ERROR DISPLAY
When operating, the control performs error detection, checking the functionality of the electronics
itself (keyboard functionality, ambient light conditions, communication between the two boards and
EN
the working temperature of the control).
If a failure is detected, the control stops all the heating elements and declares the error code,
showing on the proper display "F" and a second letter alternatively in order to identify the fault
cause (see the table below).
Error code
FA, FC
FE, Ft
Fc
Fr
FH
FJ
F0
FL
FU
Fd
Fb
F5
"Fc" Allow the cooktop to cool down.
'FA,FC,FJ,FL,FU,Fb" In case of keyboard or key errors, be sure that no objects, dirt or fluids are on
the keys / commands area. Try to remove the power and then restore it. If the problem persists, call
service.
In case of other control errors, remove and the restore the main power. If the problem persists, call
service.
20
©2020 Hestan Commercial Corporation
(CONTINUED)
Meaning
Key Error
Temperature sensor failure
Over temperature
Relay Error
Control error (EEPROM)
Key Error
Software Error
Keyboard Error (Ambient
Light)
Key Error
LED On/Off Test Error
Keyboard Error
Communication Error