Electrical Specifications - Klein Tools CL3000 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
4.
Frequency / Duty Cycle
Features:
HOLD
• Input Voltage should be between 1V-10V RMS for listed accuracy.
Resistance / Diode / Continuity
5.
AUTO
DC
V
AUTO
DC
V
AUTO
DC
V
Capacitance: < 40µF
6.
Features:
REL
HOLD
• ?
Safely discharge capacitor before measurement.
• Wait up to 60 seconds for reading.
PRESS
AUTO
DC
V
%
PRESS
TO SELECT
Resistance
Diode
Continuity
Resistance Features:
HOLD
RANGE
Do not measure resistance
on a live circuit.
Ω
< 40MΩ
Diode Features:
HOLD
Display shows:
• Forward voltage drop if forward biased.
• "O.L." if reverse biased.
Continuity Features:
HOLD
• Display shows resistance.
• Buzzer sounds if less than 30Ω
AUTO
DC
V
SYMBOLS USED ON LCD
~
AC Measurement
-
Negative DC Value
Low Battery
Auto Range Active
AUTO
%
Duty Cycle Mode
A
Current in Amps
Diode Test
F
Capacitance in Farads
µ
Micro 10
-6
k
Kilo 10
3

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement
Range
Resolution
4V
0.001V
40V
0.01V
400V
0.1V
1000V
1V
1000V DC / 750V AC RMS
Overload Protection:
Input Impedance:
10MΩ
AC Voltage Measurement
Range
Resolution
4V
0.001V
40V
0.01V
400V
0.1V
750V
1V
1000V DC / 750V AC RMS
Overload Protection:
Frequency:
50 to 60Hz
10MΩ
Input Impedance:
Response:
Averaging
AC Current Measurement
Range
Resolution
200A
0.1A
Overload Protection:
240A for 60 sec.
Frequency Response:
50 to 400Hz
Response:
Averaging
DC Measurement
REL
Relative Mode
H
Hold Active
V
Voltage Measurement
Frequency Mode
Ω
Resistance in Ohms
Continuity Test
n
Nano 10
-9
m
Milli 10
-3
M
Mega 10
6
Accuracy
± (0.7% + 2 digits)
± (0.8% + 3 digits)
Accuracy
± (0.8% + 5 digits)
± (1.0% + 10 digits)
Accuracy
± (3.0% + 3 digits)

Publicité

Table des Matières
loading

Table des Matières