Safety
Never measure resistance, diodes or capacitance on a live circuit.
Never measure resistance, diodes or capacitance on a live circuit.
Never measure resistance, diodes or capacitance on a live circuit.
Never measure resistance, diodes or capacitance on a live circuit.
Never measure resistance, diodes or capacitance on a live circuit.
Never use on DC or AC circuits over 600 V rms.
Never use on DC or AC circuits over 600 V rms.
Never use on DC or AC circuits over 600 V rms.
Never use on DC or AC circuits over 600 V rms.
Never use on DC or AC circuits over 600 V rms.
When measuring current, always switch off the supply to the circuit before
connecting the probes to the circuit.
Before any measurement, make sure that the wiring and switch are correctly
positioned.
Never open the multimeter case without first disconnecting the power supply.
Never make connections to the circuit under test unless the tester case is properly
closed.
Specifications
Dimensions
: 177 x 64 x 42 mm
Weight
: 350 grams
2 dry batteries : 1.5 volt
Duration : 300 hours or 18000 measurements lasting 1 minute with R6 batteries
: 600 hours or 36000 measurements lasting 1 minute with LR6 batteries
The tester switches itself off after 30 minutes during which no control or function has
been activated.
NB : To switch on again, switch off and on, or use the
Battery condition indicator. NB : the battery voltage is indicated approximately in
the diode function on an open circuit.
Operating temperature
Storage temperature
Relative humidity during operation :
Relative humidity during storage :
Double insulation : Installation category III - degree of pollution 2
1 standard)
Sealing
Self-extinguishing property
Radiation
Free fall
Vibration
Impact
Electric shock
Electrostatic discharge
Fast transients
Liquid crystal display, 4000 measuring points
2 measurements per second.
40 segment bar graph, speed: 20 measurements per second
for frequency and capacitance measurements).
functions. Over-range signal: the 4 on the left flashes. Arrow at the end of the bar
graph. Automatic range selection, with manual option. Suitable for measuring current
directly, and for measuring frequency.
Buzzer
Continuous beep for continuity testing
Beep interrupted each time the switch and keys are operated, and to
indicate when the range is exceeded.
.
positions)
Supplied with a protective red rubber case, 2 probe wires, an instruction manual
and 2 R6 batteries
14
!
(R6 or LR6)
:
0° to +50°C
:
-20° to +70°C
<90% RH
:
IP 50
:
V1 and V2
:
3 V/m
:
1 m
:
0.75 mm
:
0.5 Joule
:
3 kV
4 kV class 2
:
:
2 kV
.
(not fitted)
<80% RH
(up to 45°C)
(according to IEC 529)
(according to UL94)
(according to IEC 801-3)
(according to IEC 1010)
(according to IEC 68.2.6)
(according to IEC 68.2.27)
(according to IEC 801-5)
(according to IEC 801-2)
(according to IEC 801-4).
(character height 10 mm)(limited to 600 v)
Automatic display of all control signs, ranges and
(NB : No beep on the
key.
(according to the IEC 1010-
(NB : the bar graph is inhibited
key or on the V and V elec switch
, speed:

Publicité

Table des Matières
loading

Table des Matières