Screw the 230 V socket onto the mounting plate (6), connect in the built-
in wall cabinet (1) and attach to the cabinet rear wall using the screws
(7) supplied.
Note!
Carry out a functional check.
Danger!
Electrical work must be carried out only by authorised
specialist personnel!
2.
Screw the spray protection plate (8) vertically between the socket and
the connection of the frost-proof outdoor valve to the attachement
points provided on the rear wall, usng the screws provided (7).
(The spray protection plate can also be fitted after the installation of the
frost-proof outdoor valve.)
Installation of socket combi-
nation and spray protection
Installation of frost-proof
4
outdoor valve
Exposed installation
Warning!
Installation must be carried out by qualified plumbers!
1.
Insert the frost-proof outer fitting (3) into the hole and attach
using the two M6 screws (4) provided.
2.
Connect the outer fitting (3) to the water supply (copper pipe Ø 15 mm or AG R ½").
Note!
- The valve seat (thread R ½") must be located in the frost-free area.
- The specifications given under Point 1 Minimum wall thicknesses
must be observed!
© www.kemper-olpe.de – 11.2021 / K410021100001-00 – 12 /32
Note!
- Push the wall plate on to the
outlet housing as far as the stop
and adjust using the screw.
- Fit the hose sleeve and
adapter as illustrated
Concealed installation