Following figures are delivered with protection type IP 55:
21102015CH I 21109015CH
When fitting the built-in wall cabinet (1), take into account the later wall
construction of the outer façade. Max. possible compensation by the trim
frame: 20 mm!
1.
remove the pre-stamped plate for the outer fitting
2.
drill horizontally from outside to inside
Insulation without fire protection jacket.
Insulaiton on the back side is recommended (e.g. expanded polystyrene).
1.
Insert rear insulation.
2.
Insert the cabinet into the opening and fix it.
3.
If necessary, drill four holes and attach the cabinet (1) to the rear wall
using the four attachment screws provided (2) (four holes, Ø 8 mm).
Installation of built-in wall cabinet
Provide the power supply
- Note FI fuse:
Nominal fault current ≤ 0.03 A
and Connection current ≤ 32 A
- Protection type IP 44
If fire protection lagging is necessary
1.
Insert fire protection lagging into the masonry recess.
2.
Insert the cabinet (1).
* A hole of ≥ Ø 27 mm is required for the frost-proof outer fitting (3). The
pre-stamped hole in the built-in wall cabinet (1) can be used as a template.
A slope of max. 2 % must be maintained from inside to outside.
© www.kemper-olpe.de – 11.2021 / K410021100001-00 – 11 /32
Danger! Earthing!
Connect the earth cable to the
screw provided in the top of the
built in wall cabinet (all metal parts
are then earthed).