Servicing The Product; Motor; Pump; Cleaning The Product - Grundfos CRE Notice D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Servicing the product

DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply to the motor and to the
signal relays. Wait at least 5 minutes before
starting any work on the motor. Make sure that the
power supply cannot be accidentally switched on.
DANGER
Magnetic field
Death or serious personal injury
- Do not handle the motor or rotor if you have a
pacemaker.

9.1 Motor

For servicing the product, download the service instructions for
the motor by using the following link or QR code.
http://net.grundfos.com/qr/i/98413121

9.2 Pump

Service documentation is available in Grundfos Product Center
(http://product-selection.grundfos.com/).
If you have any questions, please contact the nearest Grundfos
company or service workshop.

9.3 Cleaning the product

WARNING
Electric shock
Death or serious personal injury
- Switch off the power supply to the motor and to the
signal relays. Check that the terminal box cover is
intact before spraying water on the product.
In order to avoid condensation in the motor, let the motor cool
down before spraying it with cold water.

10. Technical data

10.1 Operating conditions

10.1.1 Maximum number of starts and stops
The number of starts and stops via the power supply must not
exceed four times per hour.
When switched on via the power supply, the pump starts after
approximately 5 seconds.
If a higher number of starts and stops is desired, use the input for
external start-stop when starting and stopping the pump.
When started via an external on/off switch, the pump starts
immediately.
10.1.2 Ambient temperature
Ambient temperature during storage and transportation
Minimum: -22 °F (-30 °C)
Maximum: 140 °F (60 °C).
Ambient temperature during operation
1 x 200 - 240 and 3 x 440 - 480
Minimum: -4 °F (-20 °C)
Maximum: 122 °F (50 °C).
3 x 200 - 240
Minimum: -4 °F (-20 °C)
Maximum: 104 °F (40 °C).
The motor can operate with the rated power output (P2) at 122 °F
(50 °C), but continuous operation at higher temperatures reduces
the expected product life. If the motor is to operate at ambient
temperatures between 122 °F (50 °C) and 140 °F (60 °C), select
an oversized motor. Contact Grundfos for further information.
10.1.3 Installation altitude
If the motor is installed above 6560 ft (2000 m), it
does not comply with SELV/PELV classification.
Installation altitude is the height above sea level of the installation
site.
Motors installed up to 3280 ft (1000 meters) above sea level can
be loaded 100 %.
Motors installed more than 3280 ft (1000 meters) above sea
level must not be fully loaded due to the low density and
consequent low cooling effect of the air. See fig. 75.
P2
[%]
1
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0.91
0.90
0.89
0.88
0
0
3281 3937 4593 5249 5906 6562 7218
Fig. 75 Derating of motor output power (P2) in relation to
altitude above sea level
[ft]
63

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

CrieCrneCrkeSpkeMtreCme

Table des Matières