7.4.7 "Constant other value"
Pump variant
CME
CRE, CRIE, CRNE, CRKE, SPKE, MTRE
Any other value is kept constant.
Use this control mode if you want to control a value which is not
available in the "Control mode" menu. Connect a sensor
measuring the controlled value to one of the analog inputs of the
pump. The controlled value is shown in percentage of sensor
range.
Factory setting
See section
10. Technical
data.
7.4.8 "Constant curve"
Pump variant
CME
CRE, CRIE, CRNE, CRKE, SPKE, MTRE
You can set the pump to operate according to a constant curve,
like an uncontrolled pump. See fig. 52.
The desired speed can be set in % of maximum speed in the
range from 13 to 100 %.
H
Fig. 52 "Constant curve"
"Controller settings"
For recommended controller settings, see section
Controller settings"
7.11 "Controller" ("
Factory setting
See section
10. Technical
data.
38
"Constant other
value"
"Constant curve"
Q
).

7.5 "Analog inputs"

Available inputs depend on the functional module fitted in the
pump:
Function (terminal)
"Analog input 1, setup" (4)
"Analog input 2, setup" (7)
"Analog input 3, setup"
(14)
* See section
5.2.1 Identification of functional
If you want to set the analog input for a feedback sensor, we
recommend that you do this via the "Assisted pump setup" menu.
See section
7.41 "Assisted pump
If you want to set an analog input for other purposes, you can do
this manually.
You can set the analog inputs via the "Setup, analog input" menu.
See section
7.42 "Setup, analog
If you make the manual setting via Grundfos GO, you need to
enter the menu for the analog input under the "Settings" menu.
Function
The analog inputs can be set to these functions:
"Not active"
"Feedback sensor"
The sensor is used for the selected control mode.
"Ext. setpoint infl."
See section

7.13 "External setpoint

"Other function".
Measured parameter
Select one of the parameters listed below, i.e. the parameter to
be measured in the system by the sensor connected to the actual
analog input. See fig. 53.
5
11
1
3
13
DPT
PT
PT
TT
2
4
DPT
DPT
9
LT
Fig. 53 Overview of sensor locations
FM 200*
FM 300*
(standard)
(advanced)
-
module.
setup".
input".
function".
6
14
Q
PT
TT
12
8 16
15
7
Q
DPT DTT
PT
TT
10
LT