Troubleshooting; Diagnostic Chart - Chamberlain C2405C Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

Diagnostic Chart

Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener flash the diagnostic codes.
DIAGNOSTICCODE SYMPTOM
Flashes
Flashes
1
1
The garage door opener will not close.
1
2
The garage door opener will not close.
1
3
The door control will not function.
1
4
The garage door opener will not close.
1
5
Door moves 6-8" (15-20 cm) stops or reverses.
No movement, only a single click.
Opener hums for 1-2 seconds no movement.
1
6
Door coasts after it has come to a complete stop.
2
1-5
No movement, or sound.
3
2
Unable to set the travel or retain position.
3
3
The battery status LED is constantly flashing green.
Door is moving, stops or reverses. Opener beeps and lights
4
1-4
flash.
4
5
Opener runs approximately 6-8" (15-20 cm), stops and reverses.
4
6
The garage door opener will not close.
SOLUTION
Safety reversing sensors are not installed, connected, or wires may be cut. Inspect sensor wires for a disconnected or cut wire.
There is a short or reversed wire for the safety reversing sensors. Inspect safety sensor wire at all staple and connection points,
replace wire or correct as needed.
The wires for the door control are shorted or the door control is faulty. Inspect door control wires at all staple and connection points,
replace wire or correct as needed.
Safety reversing sensors are misaligned or were momentarily obstructed. Realign both sensors until both LEDs are glowing steady.
Make sure nothing is hanging or mounted on the door that would interrupt the sensor's path while closing.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Check
wiring connections at travel module and at the logic board. Replace travel module if necessary.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed.
Replace logic board if necessary.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed.
Replace motor if necessary.
Program travel to coasting position or have door balanced by a trained door systems technician.
Replace logic board.
Check travel module for proper assembly, replace if necessary.
Battery backup charging circuit error, replace the logic board.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. If the
door is binding or sticking contact a trained door systems technician. If door is not binding or sticking attempt to reprogram travel, see
Program the Travel page 31.
Communication error to travel module. Check travel module connections, replace travel module if necessary.
Safety reversing sensors are misaligned or were momentarily obstructed. Realign both sensors to ensure both LEDs are steady and
not flickering. Make sure nothing is hanging or mounted on the door that would interrupt the sensor's path while closing.
40

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

D2405cC2102cC2202cD2101c

Table des Matières