pecial connection '1': (Door panel + Distributor + Repeater + Monitors).
The Repeater will be connected in the distributed output of D1L-V2Plus or D4L-V2Plus distributor and can
increase the distance at 100 meters between the door panel and the repeater/s or most distant points of
the bus between the door panel and the repeater/s. Important: Read the notes that are detailed below:
A: Up to 32 ele. for distributed output and up to 128 ele. for D4L-V2Plus
EL500/V2Plus
2
FA-V2Plus
(2)
Up to 1 RD-V2Plus for each distributed output of D1L or D4L-V2Plus distributor.
( ) 1
Important: Do not exceed the max. monitors/telephones connected to a door panel/multiplexer/repeater, or the distances
indicated for door panel/multiplexer/repeater and last monitor and monitors between different apartments connected to door
panel/multiplexer/repeater. For characteristics, sections and distances see the corresponding product manual.
Note: If the repeater/multiplexer is at a distance less than 50 meters from the door panel, place in the door panel the dip
*
gain SW1-6 to OFF .
Bus: Golmar RAP-2150 cable.
Distributed output: Golmar RAP-2150 cable.
S
pecial connection
The Repeater will be connected in the distributed output of D1L-V2Plus or D4L-V2Plus distributor and
can increase the distance at 100 meters between the multiplexer and the repeater or most distant points
of the bus between the multiplexer and the repeater. Important: Read the notes that are detailed below:
A: Up to 128 ele. for riser and up to 512 ele. for multiplexer):
200m
BUS
EL500/V2Plus
25m.
2
0,75 mm
FA-V2Plus
(2)
Up to 1 RD-V2Plus for each distributed output of D1L or D4L-V2Plus distributor.
( ) 1
Important: Do not exceed the max. monitors/telephones connected to a door panel/multiplexer/repeater, or the distances
indicated for door panel/multiplexer/repeater and last monitor and monitors between different apartments connected to door
panel/multiplexer/repeater. For characteristics, sections and distances see the corresponding product manual.
*
Note: If the repeater/multiplexer is at a distance less than 50 meters from the door panel, place in the door panel the dip
gain SW1-6 to OFF .
Bus: Golmar RAP-2150 cable.
Distributed output: Golmar RAP-2150 cable.
100m
BUS
D4L-V2Plus
(2)
Sal. Dist.
25m.
2
0,75 mm
For this operation mode contact our technical support department.
'2': (Door panel + Multiplexer + Distributor + Repeater + Monitors).
*
BUS
MC-V2Plus
3m.
2
2
1,5 mm
FA-V2Plus
For this operation mode contact our technical support department.
OPERATION MODES
*
RD-V2Plus
2
FA-V2Plus
100m
RD-V2Plus
D4L-V2Plus
(2)
Sal. Dist.
2
FA-V2Plus
distributor
150m
( ) 1
Apartments
BUS
D1L or D4L-V2Plus
Up to 32 monitors
3m.
2
1,5 mm
150m
( ) 1
Apartments
BUS
D1L or D4L-V2Plus
Up to 32 monitors
3m.
2
2
1,5 mm
: