Manual Manoeuvre Or Release; Testing; Maintenance; Disposal - Nice SUMO 2000 Instructions Et Recommandations Pour L'installateur

Masquer les pouces Voir aussi pour SUMO 2000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19

4) Manual manoeuvre or release

Models SU2000 – SU2010
Pull the knob downwards to position 1.
Move the door by hand. (Figs. 16 - 16a)

5) Testing

The whole system must be tested by qualified and exper t staff who
must perform the tests required, according to the level of risk.
To test SUMO, proceed as follows:
• close the door;
• disconnect the power supply from the control unit;
• release the gear motor;
• check that the slide way is clean and fr ee from debris;
• completely open the door manually making sure to exercise a force
always less than 300N (30kg);
• check that the door does not stick when moving;
• check that when the sectional door is stopped at any point it
remains motionless;

6) Maintenance

The A924 contr ol unit featur es a maintenance LED (see the
instructions handbook for the A924 electrical power unit for fur ther
information). This signals when r outine maintenance operations ar e
required. Not only does regular maintenance offer longer life, but also
correct and safe system operation.

6.1) Disposal

SUMO comprises various types of materials which must be disposed
of in compliance with the laws of the countr y of installation.
The release device must only work when the door is stopped.
To pr ogramme and adjust anti-squash tor
instructions of the A924 control unit.
• check that the safety system and mechanical stops are in good
condition;
• check that the screw connections are perfectly tight;
• check, where present, that the chain is taut and that it slides well,
lubricate if necessary.
• after the above checks, block the gear motor and power the
control unit.
• adjust (from the electronic control unit) the force of the actuator so
that it can move just the door;
• measure the for ce of impact as r
EN1245353 standards.
Maintenance may only be per formed by qualified staff.
Maintenance involves repeating the test procedure.
There are no particular dangers or risks deriving fr om demolition of
the system.
If waste sor ting is r equired, the components should be grouped by
type of material (electrical, aluminium, plastic, etc.).
que, please see the
equired by EN12445 and
5
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sumo 2010Su2000Su2010

Table des Matières