Technical Data - Cherry ROLLERMOUSE Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7 Removing the palm rest
1 Insert the enclosed removal key into one of the both recesses on the edge of the underside of
the ROLLERMOUSE™ and turn it in the direction of the arrow.
The palm rest is released.
2 Pull the palm rest off the ROLLERMOUSE™.
8 Cleaning the device
EN
1 Disconnect the device from the PC or laptop.
2 Remove the palm rest (see 7 "Removing the palm rest").
NOTE! Aggressive cleaning agents and liquids can damage the device.
• Do not use solvents such as gasoline or alcohol and scouring agents or scouring sponges for
cleaning.
• Do not let liquid get into the device.
3 For information about cleaning the sensor, visit www.cherry.de.
4 Clean the device with a slightly damp cloth and some mild detergent (such as washing-up
liquid).
5 Dry the device with a soft, lint-free cloth.
9 Disposal
Electrical devices contain substances that can be harmful to health and the environment.
• Dispose of the device in accordance with the legal regulations.

10 Technical data

Designation
Value
Supply voltage
5,0 V/DC ±5%
Current consumption
Max. 50 mA
Storage temperature
-15 °C ... +60 °C
Operating temperature
0 °C ... +40 °C
8
11 Contact
For Europe:
Cherry GmbH
Cherrystraße
91275 Auerbach/OPf., Germany
Internet: www.cherry.de
12 Certifications
12.1 Federal Communications Commission (FCC) Radio Frequency Interference
Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.