Installation - Electrical/Electronic Components - Enduro autoSteady AS101 Manuel D'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mount the corner steady back to the bottom of the caravan (chassis) via the existing holes on the bracket (Fig.
7A) of corner steady with the original bolts/nuts.
Fully tighten all the original nuts and bolts
Adequate ground clearance: Please notice that the minimum distance between the lowest
line of corner steady and ground is 110mm, no matter what kind of chassis or installation
situation.
Re-check that all bolts/nuts have been tightened!
Mount the ground support plates (11) on the feet of the corner steady with the supplied pins and clips (Fig. 6)
The main mechanical components have now been installed.

INSTALLATION - ELECTRICAL/ELECTRONIC COMPONENTS

Make sure the 12V supply from the battery and any 230V electricity supply are disconnected.
Remove battery cable terminals and disconnect any external electrical power before starting work.
Find a suitable place for the electronic control unit (6), such as a storage area, under a seat or a bed. Make
sure this place is dry and close to the battery (40cm to 60cm). The electronic control unit can be mounted
vertically on a side wall or be mounted flat. When mounted vertically, the connections must point downwards to
avoid any short-circuits by objects falling into.
Fix the electronic control unit (6) securely into position with two screws (12). Note: if the provided screws are
not of suitable length or type for the desired location/material please substitute these as appropriate.
Drill a 25mm hole through the floor of the caravan approximately 150mm centrally in front of the control unit
terminals.
Caution! Take extra care to avoid any chassis members, gas pipes and electrical wires!
Route and connect the motor cables and battery cables in accordance with wiring diagram (Fig 8, top view of
the caravan).
The motor cables have been pre-wired already to each motor (just the motor side). Red = Positive (+) and
black is negative (-).
Open the cover on the control unit (Fig. 9A), to find the connectors for the wires.
The connectors on the electronic control unit (6):
Terminal A-
Left front motor (-)
Terminal A+
Left front motor (+)
Terminal B-
Left back motor (-)
Terminal B+
Left back motor (+)
Terminal C-
Right front motor (-)
Terminal C+
Right front motor (+)
Terminal D-
Right back motor (-)
Terminal D+
Right back motor (+)
Terminal 12V-
Main power (-)
Terminal 12V+
Main power (+)
Terminal e
Automatic draw back function
Terminal N
Not used
See also wiring diagram (Fig. 8).
Notice: Left side means the driver side for Europe continent and the passenger side for the UK.
Mark the motor cables for all motor units using the cable number markers (16). Cable number markers "A" for
left-front motor, "B" for left-back motor, "C" for right-front motor, "D" for right-back motor (Fig. 8).
Caution! Make sure that you do not reverse the positive (+) and negative (-) connections.
Incorrect connection (reverse polarity) can result in damage to the control unit!
Ensure that there is no force and movement on the cables. Also avoid any loops.
Route the motor cables along the underside of the caravan floor, and through the drilled hole.
EN
®
autoSteady 30
DURO
Ref: AS101-UM-TKI-1212-Rev. A

Publicité

Table des Matières
loading

Table des Matières