INSTALLING THE ICE MACHINE (Cont.)
ICE MACHINE LOCATION AND
PREPARATION (Cont.)
Utility and Operational Requirements
• This ice machine must be connected to a potable water
supply.
• The water supply must have a conductivity of at least 10
microSiemens/cm.
The water to this ice machine must be potable, or fit for
human consumption. During ice making some minerals
will stick to the ice making components. The higher the
mineral content, the more mineral build up will occur.
Water filters are a partial help, as they will remove
the suspended solids, but water treatment is needed
for the dissolved solids, which are part of the water
and cannot be filtered out. We recommend using a GE
Appliances Water Filter on your water inlet line such as
GE Appliances Model Number GXRLQ. Please go to www.
geappliances.com to review the installation instructions
and determine which filter will suit your application. In
Canada visit www.GEAppliances.ca.
This machine can be supplied with Reverse Osmosis
water, but the water conductivity must be no less than
10 microSiemens/cm. A reverse osmosis system should
include post treatment or blending to satisfy the R.O.
water's potential aggressiveness.
Deionized water is not recommended and could damage
the machine.
Because water softeners exchange one mineral for
another, softened water may not improve water
conditions when used with ice machines.
• Minimum water pressure: 20 psi
• Maximum water pressure: 80 psi
• Minimum water temperature: 40°F
• Maximum water temperature: 90°F.
This ice machine is designed to operate in a wide range
of air temperatures with a minimum air temperature of
50°F and a maximum air temperature of 100°F.
Although the machine will function within the listed
ranges, it works best at water temperatures between
50°F and 60°F and air temperatures between 60°F and
80°F.
NOTE: Ice making capacity goes down as the
environmental temperatures go up, and will be severely
reduced at temperatures over 90°F.
Operating a unit outside of the limits can cause problems
that are not covered by the warranty and, if extreme,
cause damage to the unit.
10
Installation Instructions
ICE MACHINE LOCATION AND
PREPARATION (Cont.)
This machine can be built into a cabinet. It is an air cooled
refrigeration system. Air flows in and out of it through the
grill at the bottom front. The grille must not be blocked by
any covering door, or other obstruction.
Warm Air Out

ADVANCE PLANNING

CAUTION
Due to excessive weight, TWO
PEOPLE ARE REQUIRED TO MOVE AND INSTALL THIS
Ice maker. Failure to do so can result in back or
other injury.
CUTOUT & PRODUCT DIMENSIONS
Air Intake

Publicité

Table des Matières

Dépannage

loading

Table des Matières