IMPORTANT!

Please Read Before Starting

This air conditioner must be installed by the sales dealer or
installer.
This information is provided for use only by authorized
persons.
For safe installation and trouble-free operation, you
must:
G
Carefully read this instruction booklet before beginning.
G
Follow each installation or repair step exactly as
shown.
G
This air conditioner shall be installed in accordance
with National Wiring Regulations.
G
Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard
or unsafe practice which can
WARNING
result in severe personal injury
or death.
This symbol refers to a hazard
or unsafe practice which can
CAUTION
result in personal injury or prod-
uct or property damage.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help for
a special problem, contact our sales/service outlet or
your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING
When Wiring
ELECTRICAL SHOCK CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH.
ONLY A QUALIFIED, EXPERIENCED
ELECTRICIAN SHOULD ATTEMPT TO
WIRE THIS SYSTEM.
‡ 'R QRW VXSSO\ SRZHU WR WKH XQLW XQWLO DOO ZLULQJ DQG WXE
ing are completed or reconnected and checked.
‡ +LJKO\ GDQJHURXV HOHFWULFDO YROWDJHV DUH XVHG LQ WKLV
system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections
and inadequate grounding can cause accidental
injury or death.
‡ *URXQG WKH XQLW following local electrical codes.
‡ &RQQHFW DOO ZLULQJ WLJKWO\ /RRVH ZLULQJ PD\ FDXVH
overheating at connection points and a possible fire
hazard.
‡ 7R SUHYHQW SRVVLEOH KD]DUGV IURP LQVXODWLRQ
failure, the unit must be grounded.
‡ ,QVWDOO D SURWHFWLYH leakage breaker/fuse link depend-
ing on the installation location (especially a damp or
humid location). If a leakage breaker/fuse link is not
installed, electric shock can occur.
When Transporting
Be careful when picking up and moving the indoor and out-
door units. Get a partner to help, and bend your knees when
lifting to reduce strain on your back. Sharp edges or thin
aluminum fins on the air conditioner can cut your fingers.
When Installing...
Select an installation location which is rigid and strong
enough to support or hold the unit, and select a location
for easy maintenance.
...In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the
unit's weight. It may be necessary to construct a strong
wood or metal frame to provide added support.
...In a Room
Properly insulate any tubing run inside a room to prevent
"sweating" that can cause dripping and water damage to
walls and floors.
...In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide
a solid, level foundation for the outdoor unit. This pre-
vents water damage and abnormal vibration.
CAUTION
When Connecting Refrigerant Tubing
WARNING
‡ 9HQWLODWH WKH URRP ZHOO LQ WKH HYHQW WKDW UHIULJHUDQW
gas leaks during the installation. Be careful not to allow
contact of the refrigerant gas with a flame as this will
cause the generation of poisonous gas.
‡ 'R QRW DGG DQ\ UHIULJHUDQW DLU RU VXEVWDQFH LQWR WKH
refrigeration circuit other than the designated refriger-
ant (R410A). Adding anything other than the specified
refrigerant may cause the pressure to rise excessively
in the refrigeration circuit, rupturing the circuit and
causing injury or damage.
‡ 8VH DOOQHZ WXELQJ DQG IODUH QXWV WR PDNH WKH WXELQJ
connections. Using any previous parts (from R22-
based systems) may result in damage to the equip-
ment, and may lead to the refrigeration circuit ruptur-
ing, causing a serious accident.
2
Keep the fire alarm and the air
outlet at least 1.5 m away from
the unit.
‡ :KHQ SHUIRUPLQJ piping work
do not mix air except for
specified refrigerant (R410A)
in refrigeration cycle. It caus-
es capacity down, and risk of
explosion and injury due to
high tension inside the
refrigerant cycle.
‡ 5HIULJHUDQW JDV OHDNDJH PD\
cause fire.
‡ 'R QRW DGG RU UHSODFH UHIULJHU
ant other than specified type.
It may cause product dam-
age, burst and injury etc.