Technical Specifications - Endress Professional GT Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 92

Technical specifications

Checking the electrical safety
7
Technical specifications
Technical
specifications
Designation
Model
Generator
Frequency / Protection
Class
Rated voltage
Max. power output (LTP)
VA
Continuous power (COP)
in watts
Nominal output factor
cos/ (phi)
Engine type
Cubic capacity in cm³
Output (3000 rpm) in kW
Tank capacity (litres)
Sound power level at
workplace L
*
pA
Sound power level at
a distance of 7m L
pA
Sound power level ** L
Length in mm
Width in mm
Height in mm
Weight kg
Engine oil quantity
* measured at a distance of 1 m and a height of 1.6 m in accordance with ISO 3744 (Part 10)
** measured in accordance with ISO 3744 (Part 10)
38
The technical specifications concerning use of the generator
are described in this section.
ESE 206 HS-GT
synchronous
50 Hz / IP 23
230 V 1~
2900
2200
0.9
Honda GX160
1-cylinder 4-stroke
OHC, air-cooled
163
2.5
20
88dB(A)
71dB(A)
**
96dB(A)
WA
637
473
500
41
0.6 litres
Table 7.1: Technical Specifications for the Generator T1
ESE 306 HS-GT
synchronous
50 Hz / IP 23
230 V 1~
3400
2600
0.9
Honda GX200
1-cylinder 4-stroke
OHC, air-cooled
196
3.3
20
89dB(A)
71dB(A)
96dB(A)
637
473
500
43
0.6 litres
ESE 406 HS-GT ES
synchronous
50 Hz / IP 23
230 V 1~
5100
3900
0.9
Honda GX270
1-cylinder 4-stroke OHC,
air-cooled
270
4.6
30
89dB(A)
72dB(A)
97dB(A)
800
538
576
61 / 66 (E-Start)
1.1 litres

Publicité

Table des Matières
loading

Table des Matières