Operating Instructions (ON BOARD CONTROLS)- See Figure 16
The unit can be operated using the manual controls which are located on the upper right of the
fireplace. See Fig. 16
Icon
Function
0
I
Standby Switch
Menu Cycle Button
+
Increase "+" Button
-
Decrease "-" Button
User Modes:
Mode Name /Description
Disable/Enable Heat Options
on product
Switch from Degree Celsius to Degree
Fahrenheit.
SmartSense Mode selection.
Description
Turns product on to Standby mode. When pressed to "I", Display Board show
"ST.BY" for five seconds, then shows "." only, to indicate standby condition.
After initial power up, product is on standby. Press Menu Cycle Button Once: This
turns on the flame effect to a default setting. Display Board show "ON".
This button cycles through the Product setting options, when the product is
operating. These options are "FIRE", "AMB", "HEAT", "Set.T", "TIMR", "SNSR" and
"VOL".
"FIRE": The Flame Brightness Setting can then be adjusted using the "+" or "-"
buttons. There are seven
levels of brightness, "-F6-" for Pulsating Effect and "OFF" when the flame effect is
turned off.)
"AMB": The Ambient Setting can then be adjusted using the "+" or "-" buttons.
There are seven settings available on the onboard controls. (Display shows "AMB1"
to "AMB7") "AMB8" is a customisable mood setting that is available via the Dimplex
Flame Connect App. Please Note: "-F6-" is not an available setting when in "AMB6",
"AMB7" or "AMB8".
"HEAT": The set temperature "XXST" is displayed for two seconds, after that, the
room temperature "XX°C" for a further two seconds. The Heat Setting can be
switched ON/OFF using the "+" or "-" buttons respectively. (Display shows "ON" or
"OFF")
"Set.T": The Set Temperature can then be adjusted using the "+" or "-" buttons.
Temperature range is 15°C - 32°C and is in increments of 1°C (Display shows "15ST"
up to "32ST") After 2 seconds, the current Room Temperature is displayed "XX °C".
This is shown for three seconds.
"TIMR": The Runback Timer can be adjusted using the "+" or "-" buttons. This can
be set between 0.5 Hrs and 8.0 Hrs in increments of 0.5 hrs. ("0.5Hr" to "8.0 Hr")
"SNSR": The SmartSense Settings can be adjusted using the "+" or "-" buttons.
"MIN" turns product off 0.5 hour after last movement detected."MAX" turns product
off 3 hours after last movement detected. "OFF" - Motion Sensor turned off.
"VOL": The
Volume can be adjusted using the "+" or "-" buttons. Volume has seven
settings. ("OFF", which is sound off and "VOL1" to "VOL6")
This button increases the displayed setting when it is pressed, while in Menu Mode.
This button decreases the displayed setting when it is pressed, while in Menu Cycle
Mode.
Action (Actions cannot be input by remote control)
When in heat, press both the Menu Cycle Button and "-" Button for five seconds.
Display reads "CD02", heat is now disabled. Repeat to enable Heat.
When in heat, press both the Menu Cycle Button and "+" Button for five seconds.
The product can then switch from "-°C-" to "-°F-". Repeat to revert back to degrees
Celsius mode.
"24Hr" setting operates the SmartSense at all times. This is the default setting.
"HOME" setting; the product operates the SmartSense between 5pm and 11pm.
Please Note: The product must be connected to the "FLAME CONNECT" App, for
the"HOME" setting to operate.