Fitting panel – After Installation
The Back Panel can also be change after the product has been installed, a person of suitable
competency is required to carry out this task. Please follow the steps below.
1. Unplug product from Power Supply and remove front trim on unit. See Fig. 2
2. Remove Front Glass from product and store in a safe place. (A suction cup is provided to help
remove/place the front glass.) See Fig. 6
3. Remove Fuelbed fixing screws, then remove Fuelbed. (Fig. 7)
4. Remove both Side Glasses by moving them out at the bottom, then sliding out to remove. Store
these in a safe place. (Fig. 8).
5. Remove plastic Inner Screen by tilting it from the base. (Fig.9)
6. Remove Back Inner Panel bracket (Fig. 10A), Inner Back panel can then be tilted and removed
from its housing. (Fig. 10B)
7. Replace with new Back Inner Panel, and reverse the steps set out above, to re-assemble the
product. Ensure Inner screen is reassembled correctly. (Smooth mirrored finish to face the front of
the product.)
Step 3: Installing the Product
CAUTION: Two people will be required for various steps of this procedure.
This product is designed to be installed into existing block wall or a custom-built studded wall
structure. Please consult a competent installer before undertaking this to ensure a safe and
secure installation. If installing into an existing chimney or flue, please ensure that the chimney or
flue is blocked off. This is to prevent up-draughts affecting product operation.
Electrical Requirements
NOTE: A dedicated, properly fused 13 Amp circuit is required, rated for the appropriate voltage
(230-240V). An isolation switch should also be incorporated in cases where the product plug is
inaccessible after installation.
WARNING: Construction and wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, electric shock or injury to persons, always use a licensed
electrician.
1. Using the product dimensions (Fig. 11), build a suitable structure for the product to fit into.
Ensure that, when installed, the product is within 1m of a power outlet. Please refer to Electrical
Requirements section above for more details.
It is recommended that the base of the unit is installed between 200mm and 800mm from the
floor. This is to maintain an optimised viewing angle of the fire effect. (See Fig. 12)
The product must not bear the weight of the finished wall located above it. Consider the use of a
lintel for appropriate support.
2.Using any combination of the three fixing methods (Fig. 13 a,b,c), fix the product to its supporting
structure.