Extended functions
These functions can only be selected/set if the device is in programming mode
(button
).
• Predefined light values
• Predefined time setting
• Impulse mode activation
• Holiday mode
• Alarm mode
• Anti-creep protection ON/OFF
• Focus LED ON/OFF
• Electronic range adjustment
• Reset (resets to factory settings)
NB: The special impulse, holiday and alarm mode functions cannot be used at the same time.
The program activated most recently is active.
Button
Function
Opens programming mode
Indicated by flashing focus LED.
The set values are active once programming mode is closed
automatically activated after 5 minutes.
Closes programming mode
Loaded test mode (LTM)
During the test mode, the focus LED remains permanently on. Regardless
TEST
of the ambient brightness, if motion is detected, the detector switches the
device and the blue mode LED ON for 1 second and OFF for 2 seconds.
Exit test mode by pressing the
Load-free test mode (LFTM)
During the test mode, the focus LED remains permanently on.
Regardless of the ambient brightness, if motion is detected, the blue mode
LED will switch ON for 1 second and OFF for 2 seconds. Exit test mode by
pressing the
button.
RESET
NB: The load-free test mode (LFTM) function is deactivated in the factory
settings. Activation or deactivation is only possible during the self-test. Switch
the power supply on and press the
free test mode (LFTM) function is now activated. To disable this function, press
during self-test again the
mode the
button (resets factory settings).
RESET
or are
button.
RESET
button during the self-test. The load-
TEST
button or while the device is in programming
TEST
Setting the light values (programming mode)
Day and night operation
The sun is starting to set (approx. 100 lux)
The sun is almost set (approx. 25 lux)
Night operation (approx. 2 lux)
Storing the current light value
Stores the current light value.
On-period (programming mode)
Adjustable from 15 seconds to 30 minutes.
Impulse mode (programming mode)
Impulse means that the device is activated for 1 second followed by a
break of 9 seconds in which no movement is detected. The red focus
LED flashes twice for each sequence. After the break, a new sequence is
triggered if motion is detected. This is suitable, for example, for controlling
automatic stairwell lights or a doorbell.
Continuous lighting ON/OFF
System can be switched ON or OFF, independently of motion or ambient
brightness, for 12 hours max.
NB: To prevent tampering, the continuous lighting OFF function is disabled in
the factory settings. Activation is only possible during the self-test. Switch the
power supply on and press the
continuous light OFF function is now enabled.
To disable this function, press the
RESET
programming mode. (Resets factory settings).
button during the self-test. The
button when the device is in
11
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

El10026041

Table des Matières