4.1 Loaded test mode (LTM)
Regardless of the ambient brightness, if motion is detected, the detector switches the
device and the blue mode LED on for 1 second and off for 2 seconds.
4.2 Load-free test mode (LFTM)
Regardless of the ambient brightness, if motion is detected, the blue mode LED will switch
on for 1 second and off for 2 seconds.
GB
NB: The load-free test mode (LFTM) function is deactivated in the factory settings. Activation or
deactivation is only possible during the self-test. Switch the power supply on and press the
button during the self-test. The load-free test mode (LFTM) function is now activated. To disable
this function, press during self-test again the
mode the
button (resets factory settings).
RESET
The following possibilities are available to adjust the field of detection to the surrounding area:
• Turning the sensor head horizontally by +/- 90° (unlock sensor head first, see Fig. 6). The
central position is indicated by the red arrow.
• Adjust the range for each sensor field by mechanically adjusting the internal
lens mask (Fig. 7.2). The position is displayed optically by the red focus LED (Fig. 8).
• Use of the supplied, customisable covering cap for masking specific areas (Fig. 9).
Once the field of detection is set, turn the operation selector switch to "
the adjustments using the setting elements on the device, or to "
the factory settings or to make other settings using the remote control.
5 • OPERATION/PROGRAMMING
Every time movement is detected the red focus LED briefly flashes twice. This function can
be switched off (see section 6). Depending on the set light value, the motion detector will
switch the system on for the on-period.
Setting element: operation selector switch (Fig. 7.1)
NB: The operation selector switch allows you to set the parameters for the device. You can
either simply select the values using the setting elements (Fig. 7.3 and 7.4) on the device or use
the factory settings, or the parameters set using the remote control. You can toggle the settings
at any time; the defined values apply.
Test mode:
Manual mode
:
Auto/RC mode
: Device operates according to the factory settings or the
Factory settings
Set the operation selector switch (Fig. 7.1) to "
defined with the remote control, the detector operates according to the factory settings.
These consist of a fixed value for the on-period, the electronic setting for the range and
10
button or while the device is in programming
TEST
See Test mode section
Device operates according to the parameters set via the
setting elements (Fig. 7.3 and 7.4) on the device.
parameters defined using the remote control.
". If no values have yet been
the light value (2 min/max. electronic range/10 lux). The values can be individually
modified using the remote control. To return settings to the original default values, press
the Reset button (ensure that you are in programming mode) on the Mobil-RCi remote control.
Setting element: on-period (Fig. 7.3)
Adjustable on-period: impulse, 15 seconds – 16 minutes (up to 30 minutes via Mobil-RCi
remote control). Impulse means that the device is activated for approx. 1 second followed
by a break of 9 seconds in which no movement is detected. The red focus LED flashes twice
for each sequence. After the break, a new sequence is triggered if motion is detected. This
is suitable, for example, for controlling automatic stairwell lights or a doorbell.
TEST
Setting element: light value (Fig. 7.4)
The light value is infinitely variable between 2 – 2500 lux.
Setting element: range adjustment (Fig. 7.2)
The controller for setting the range is independent of the operation selector switch setting.
Range adjustment: from approx. 16 m – approx. 5 m.
6 • REMOTE CONTROL
NB: To be able to use the Mobil-RCi remote control, the operation selector switch must be set to
" to make
"
" to run
have not yet been input by remote control, the device will operate according to default factory
settings (10 lux/2 min/max. electronic range).
All settings programmed by remote control are permanently stored in the memory
and will not be lost in the event of a power failure.
Using the Mobil-RCi and Mobil-RCi-M remote control (Fig. 10) the settings can be easily
programmed without needing to climb a ladder or use any tools. For optimum reception,
when programming the settings, point the remote control at the motion detector. Please
note that if the sun shines directly on the sensor, the standard detection range of approx.
6 m may be dramatically reduced owing to the sun's infrared rays.
6.1 Acknowledgement of commands:
Red focus LED and blue LED flash twice alternately.
6.2 Standard functions/programming mode
There are basically two different options for entering values via the remote control.
Standard functions
These functions can be selected directly:
• Test mode
• Continuous lighting ON/OFF
• Storage of current light value
• Reset (resets the current modes)
• Master X (cancels the time setting)
• Programming mode
" (Fig. 7.1). If the selector switch is set to "
" and settings