3. INSTALLATION AND CONNECTION (continued)

3.4 Electrical Connection

The electrical installation and wiring of this equipment must comply
with local installation standards.
F
NF C15-100
D
DIN VDE 0100-702
A
ÖVE 8001-4-702
E
UNE 20460-7-702 1993,
RECBT ITC-BT-31 2002
IRL
Wiring Rules + IS HD 384-7-702
I
CEI 64-8/7
LUX 384-7.702 S2
NL
NEN 1010-7-702
P
RSIUEE
Check that the available electrical power supply and the network
frequency correspond to the required operating current, taking into
account the appliance's specific location and the current needed to
power any other appliance connected to the same circuit.
HP3005AT1RM 230 V
See the corresponding wiring diagram in the appendix.
The connection box is located on the right side of the unit. Three of the
connections are for the power supply and two are for the filtration pump
control (Servo control, OUT2).
GB
EW
H
M
PL
CZ
SK
SLO
TR
+/- 10 % 50 Hz 1 Phase
= =
= =
L N
1 2
Dry contact 7A max
Power supply
potential free.
230V
/ 50Hz
Priority heating function
BS7671:1992
EVHS-HD 384-7-702
MSZ 2364-702/1994/MSZ 10-553 1/1990
MSA HD 384-7-702.S2
PN-IEC 60364-7-702:1999
CSN 33 2000 7-702
STN 33 2000-7-702
SIST HD 384-7-702.S2
TS IEC 60364-7-702