During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code
transmitters (self-learning and Dip Switch).
Soft start is enabled or disabled.
On: Starting is performed at reduced speed for 2s and then movement is
SOFT
restored to normal speed.
Off: Soft start is disabled.
The movement reversion during opening after the activation of the anti-
crash device (amperometric sensor) is enabled or disabled.
On: enabled reversion. The amperometric sensor activation causes the
INvA
movement reversion.
Off: disabled reversion. The amperometric sensor activation causes the
movement stop.
Enables or disables door stop before the opening mechanical stop
ON: The control unit stops the door around 5 cm before the mechanical
SASO
stop.
In this way stop is progressive and without vibrations.
OFF: The control unit stops the door on the opening mechanical stop
The photocell checks are activated or deactivated. Before the closing ope-
ration, the control unit checks the switching of the photocell contact. If the
tst1
checks are not successful, the door will not close.
On: activated check on photocell
Off: deactivated check on photocell
The "ESA" energy savings function is activated or deactivated.
On: Enabled energy savings. After around 10 sec of non-operation, the po-
wer supply is cut off from the accessory output and the system switches to
esa
stand-by.
Off: Disabled energy savings. This is to be used should the accessory power
supply output is to be always activated, e.g. if keypads powered at 24VDC
or other devices that need to be always powered, are used.
The remote storage of the radio transmitter codes is enabled or disabled (see
par. REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
mENU
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the step-
by-step function.
PP
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver is waiting for (Push) a transmitter code to be assigned to the second
radio channel.
2Ch
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
When this function is selected, the receiver awaits (Push) a transmitter code to be assigned to the SAIR
function (see SAIR parameter).
Sair
Press the transmitter key, which is to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.