Festo HMPL KP Série Notice D'utilisation page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
HMPL−...−KP
Fitting the clamping unit
Carry out the following steps:
S
1. Exhaust the HMPL−... and if necessary dismantle it.
2. Place the piston rod of the HMPL−... by hand in the extended end position.
3. Place the flange 1 and the housing 3
together with the centring sleeves pro
vided on the HMPL−... .
In order to move the clamping rod, you
must press the manual device 5 on the
clamping unit.
4. Tighten the fastening screw in the hole of
the flange. The tightening torques are
shown in Fig. 6.
Component
Tightening torque
Fastening position
Mounting combination
Number of fastening
screws (M5x55 DIN 912;
in some cases supplied)
Screw−in depth L
Fig. 6
16
Fig. 5
Housing 3
5.9 Nm
On the basic profile of the
HMPL−...
Fitting to the fastening plate
Fitting to a second HMPL−...
using the screws provided
(M5 x 45)
Min. 2
Max. 38 mm
5
Flange 1
5.9 Nm
Front plate
1
Festo HMPL−...−KP 0501a English
3
1

Publicité

Table des Matières
loading