Problem
Negative tone when pressing the
bell push button.
Speech and other functions (e.g.
door opener) are working, but
there is no image.
The image is completely
disturbed and unrecognisable
(striping, ...).

7. TECHNICAL DATA

Dimensions: .......................175 x 104 x 16 (19) mm (HxWxD)
Ambient temperature:.........-20 – 50°C
Housing material: ...............aluminium/acryl glass
Power consumption: ...........active I(P) = 180 mA – passive I(P) = 125 mA – I(a) = 0.4 mA
Power supply voltage: .........24 Vdc ± 8%
Camera: .............................CCD sensor 420 lines

8. WARNINGS REGARDING INSTALLATION

- The installation should be carried out by a registered installer and in compliance with the statutory
regulations.
- This user manual should be presented to the user. It should be included in the electrical installation file,
and it should be passed on to any new owners. Additional copies are available on the Niko website or via
the Niko support service.
- During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this user manual, which only states general regulations and should therefore be read within the scope
of each specific installation.
- the rules of proper workmanship.
- In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko
support service (Belgium: +32 3 778 90 80 – United Kingdom: +44 1525 877 707) or your wholesaler.
Contact details and more information can be found at
EN
Cause
Programming error or
associated internal unit not
correctly installed.
Installation in programming
mode.
The internal or external unit
receives no power.
V1 and V2 are reversed.
light sensitivity: 0.2 lux
focal distance: 3.7 mm
diagonal opening angle: 90°
video output: 1 Vpp, symmetrical
Erase programming, then restart
programming.
Quit programming mode.
Check cabling on the power
supply, internal unit and external
unit using the wiring diagram.
Reverse the conductors.