Testing For Gas Leaks - Electrolux ECFD3068AS Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

30" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Important Notes for Gas Connection:
• The appliance and its individual gas shutoff valve
must be disconnected from the gas supply piping
system during pressure testing of the system at
test pressures in excess of 1/2 psi (3.5kPa).
• The appliance must be isolated from the gas sup-
ply piping system by turning off its individual man-
ual shut-off valve during pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psi (3.5kPa).

Testing for gas leaks

WARNING
NEVER use a flame to check for
gas leaks.
Gas leak tests should be performed before the test-
ing the electric ignition of the burners:
1. Turn on gas supply.
2. Apply a non-corrosive leak detection fluid (e.g.
soapy water) to all joints and conduits.
3. If bubbles appear, it means there is a leak. Turn
off the gas supply and tighten the connections.
4. Retest for leaks. If no bubbles appear, the test is
passed. Wipe off all residues of detection fluid.
Testing the electric ignition of the
burner
This test should be performed after the range and
supply line connectors have been carefully checked
for leaks and the range connected to the electric
power supply:
1. Push in and turn a surface burner knob to the low
flame position. You will hear the igniter sparking.
2. The surface burner should light when gas is sup-
plied to the cooktop burners. Each burner should
light within four (4) seconds, after air has been
purged from supply lines. Visually check that
burner has lit.
3. Once the burner lights, the control knob should
be rotated out of the low flame position.
4. There are separate ignition devices for each
burner. Try each knob separately and together
until all burner valves have been checked.
Adjusting the minimum gas setting
Circular Dual Flame burners
NOTE: The Circular Dual flame burners are fitted
with two minimum adjustment screws. They are
slotted head and brass coated located at both
sides of the knob insertion rod.
1. Push in the burner control knob and light it at the
minimum position
2. Remove the burner control knob, along with the
conical spring and knob ring.
3. Tighten or loosen the highlighted screws to adjust
the minimum flame height.