What To Do If The Air Conditioner Does Not Work; Technical Specifications - Vitrifrigo STR6000 Manuel D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9

WHAT TO DO IF THE AIR CONDITIONER DOES NOT WORK

Problem
The conditioner does not start
The air conditioner does NOT
cool sufficiently
The
air
conditioner
cools
excessively
The air conditioner does not stop
10

TECHNICAL SPECIFICATIONS

Cooling power
Voltage
Current absorption
Operating temperature range
Coolant
Cooling quantity
CO2 equivalent
Global warming potential (GWP)
Sound emission
Dimensions (L x D x H)
Weight
Possible cause(s)
Electrical power supply
Setpoint
Fan speed
Operating mode
Setpoint
Fan speed
Operating mode
Cab temperature
Try running a reset
Parameter
Solution
Reconnect the power connector correctly
Check that the unit's main power switch is turned
on
Check that the battery disconnect device is not
disconnected
Check that the 50 A fuse on the power cable is
intact
Check that the power supply cable of the unit is
correctly connected and not interrupted
Check that the battery is efficient and that there
are no traces of oxide on its poles and/or joints
Check that the battery is charged
Check that the voltage measured on the power
connectors
of
excessively lower than that of the battery
set the setpoint to a lower value
Set a higher fan speed
set the AUTO mode for maximum performance
Set the setpoint to a higher value
Set a slower fan speed
set the ECO mode
The cab temperature is very high or the setpoint
temperature has been set too low
Disconnect the power supply, wait one minute
and reconnect it. Try to turn it back on
Value
660 x 910 x 288 mm
Approximately 22.5 kg
38
the
air
conditioner
is
not
1700 Watt
24 volts
max 30 A
+5 to +43°C
R134a
0.400 kg
0.572 t
1430
< 70 dB(A)