5
ConstruCtion, layout & Controls
Controls & Indications
The description and the functions of the controls and indications are given below:
Front Panel
Charge Status LED Indications
LED STATE
Blinking Green
- 1 Green Blink
- 2 Green Blinks
- 3 Green Blinks
- 4 Green Blinks
- 5 Green Blinks
Solid Green
Solid Orange
Solid Red
Blinking Red
Push Buttons
BUTTONS
Display
Reset Amp-Hours
Equalization
Start/Stop
34
Charging is in the state of Bulk or Absorption
depending upon the number of blinks as follows:
For 12 V Battery
> 0.75 V below
Absorption Voltage setting
0.75 V below
Absorption Voltage setting
0.5 V below
Absorption Voltage setting
0.25 V below
Absorption Voltage setting
At Absorption Voltage setting
Charging is in the state of Float
Charging is in the state of Equalization
Charging is in the state of fault: Over current or low DC voltage
or operating temp below 0°C (32°F)
Charging is in the state of fault: Over Temperature
Push to change the display as in Fig. 5.3.
Push and hold to reset Amp-Hours.
When DIP Switch 5 is set at OFF, hold Restart/Stop Equalization for 5 sec
to manually start equalization. Press it for 2 sec to stop equalization.
INDICATION
For 24 V Battery
> 1.5 V below
Absorption voltage setting
1.5 V below
Absorption Voltage setting
1.0 V below
Absorption Voltage setting
0.5 V below
Absorption Voltage setting
At Absorption Voltage setting
ACTION