Loss of Battery Capacity at Low Temperatures
Batteries lose capacity in low temperatures. At 32 ºF (0 ºC), a battery will deliver
about 70 to 80 % of its rated capacity at 80 ºF (26.7 ºC). If the electrolyte temperature
of the battery bank is lower than 80 ºF (26.7 ºC), additional batteries will be needed to
provide the same usable capacity. For very cold climates, an insulated / heated battery
compartment is recommended.
Freezing of Electrolyte
For applications with low ambient temperature, the lead-acid battery must also be
protected against freezing of the electrolyte. The risk of freezing depends on the state
of charge. The chart given below illustrates the freezing limit as a function of the state
of charge.
Series and Parallel Connection of Batteries
Series Connection
Solar Charge Controller
SCC30-AB (rear view)
When two or more batteries are connected in series, their voltages add up, but their
AH capacity remains the same. Fig. 3.2 above shows 4 pieces of 6 V, 200 AH batteries
connected in series to form a battery bank of 24 V with a capacity of 200 AH. The
GENERAL INFORMATION: BATTERIEs
- 20°
- 20°
- 40°
- 40°
slushy until hard
slushy until hard
- 60°
- 60°
- 80°
- 80°
0
0
20
20
Cable "A"
Battery 4
PV +
PV -
BAT +
6V Battery
BAT -
Cable "B"
Fig. 3.2. Series Connection
40
40
60
60
80
80
100
100
State of charge [%]
State of charge [%]
Battery 3
Battery 2
6V Battery
6V Battery
6V Battery
3
Battery 1
6V Battery