CHECKING THE INSTALLATION SITE

Clearances and dimensions

To install the range, refer to the following figure.
CAUTION
CAUTION
allowable wood cabinet temperatures of 194 °F. Make sure the wall covering,
countertops, and cabinets around the range can withstand the heat (up to 194 °F)
generated by the range. If not, discoloration, delamination, or melting may occur.
Hatched Faces should
be flat and leveled.
4-1/2"
36"~36-4/5"
23-1/5"
6-3/10"
29-4/5"
A : Cabinet opening min 30" (76.2 cm)
B : Acceptable electrical outlet area
If your cabinets are over 36-4/5" high, you must install this range on a hard, heat
resistant support that raises the surface of the range so that it is about even with
the countertop.
CAUTION
CAUTION
freestanding cutout cabinet. For more information, see "Optional rear filler kit" as shown
below.

Optional rear filler kit

Used to fill gap between the range back and wall. Adds a filler strip to the rear of the
range. This kit can only be used when the opening in the countertop is 25" deep.
Install_NE58H9970WS_AA_AC_DG68-00594A-05_EN+MES+CFR.indb 5
This range has been designed to comply with the maximum
SLIDE-IN CUTOUT
3"
1" min.
24"
3"
23-3/16"
35-7/8"
31"
26-3/10"
B
28-3/5"
A
6"
24-7/10"
48"
26-3/10"
You must use the rear filler kit to install the range in a
English - 5
FREESTANDING CUTOUT
1/2" min.
25"
25"
6"
If the countertop depth is
greater than 25", there will
be a gap between the filler kit
and the back wall.
3"
24"
3"
B
A
2017-08-11