Connection With The Mains; Operation; Stand Alone-Operation; Dmx-Controlled Operation - EuroLite LED PAR-64 UV Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After you connected the spot to the mains, the EUROLITE LED PAR-64 UV Spot starts running.

Stand Alone-OPERATION

The LED PAR-64 UV Spot can be operated without a controller.
In order to select STATIC UV, set dip switch 1 to ON.

DMX-controlled operation

You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.

Addressing the device

Set dip switch 10 to ON.
Dip switches 1 - 9 set the DMX address.
International
L
N
18/39
resistor
51913700_V_1_0.DOC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Uv spotLed par-38 rgb

Table des Matières