Caution: Devices may cause severe injuries when crashing down! If you have doubts concerning the safety
of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the device with the mounting-bracket to your trussing system using an appropriate clamp.
For overhead use, always install a safety-rope that can hold at least 12 times the weight of the fixture. You
must only use safety-ropes with quick links with screw cap. Pull the safety-rope through the hole in the
mounting-bracket and over the trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

DMX-512 connection / connection between fixtures

The wires must not come into contact with each other, otherwise
Please note, the starting address depends upon which controller is being used.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.

DANGER OF FIRE!

DANGER TO LIFE!

the fixtures will not work at all, or will not work properly.