Installation; Installing/Replacing The Lamps; Danger To Life; Rigging - EuroLite B-10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Installing/Replacing the lamps

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need two 230 V/40 W E-14 lamps.
During the operation, the lamp reaches temperatures of up to 240° C.
Procedure:
Step 1: Unscrew the screws on top of the ball.
Step 2: Remove the ball from the housing cover.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Put the new 230 V/40 W E-14 lamp into the lamp-socket.
Step 5: Replace the ball onto the holder.
Step 6: Tighten the screws.

Rigging

When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
The device can be installed on the ground or on the wall or ceiling.

Hanging installation

DANGER TO LIFE!

Only install the lamps with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened housing-ball!

DANGER OF FIRE!

14/31