LiftMaster LJ8900W Manuel D'instructions page 14

Masquer les pouces Voir aussi pour LJ8900W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
MOUNTING THE SAFETY REVERSING SENSORS
1.
Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor.
2.
Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing
toward each other across the door. Be sure the lens is not obstructed by a bracket
extension.
3.
Finger tighten the wing nuts.
Wing Nut
WIRE THE SAFETY REVERSING SENSORS
1.
Run the wire from both sensors to the door operator. Attach the wire to the wall and
ceiling with the staples.
2.
Strip 7/16" (11 mm) of insulation from each set of wires. Separate the wires. Twist
the white wires together. Twist the white/black (or full black) wires together.
3.
Insert the white wires into the white terminal on the door operator. Insert the white/
black wires into the grey terminal on the door operator. To insert or remove the
wires from the terminal, push in the tab with a screwdriver tip.
7/16
(11 mm)
WHT
WHT/ BLK
or
Full Black
Carriage Bolt
Bell wire
14
HARDWARE
Carriage Bolt
1/4"-20x1/2" (2)
Wing Nut
1/4"-20 (2)