Thermador PROFESSIONAL VCIN JP Série Manuel D'installation page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 36: VCIB Secure Liner Front & Back
6. Install the Unit
a) Install the custom insert inside the custom hood.
b) Secure to the rear of the frame using six (6) 2"
(50.8 mm) mounting screws provided (Figure 37).
2" (50.8 mm)
X6 mounting
screws
c) Secure to the sides of the frame using six (6) 2"
(50.8 mm) mounting screws provided (Figure 38).
2" (50.8 mm)
mounting screws
X3 per side
½" (12.7 mm)
X6 each front
& back side
Figure 37: VCIB Rear Screws
Figure 38: VCIB Side Screws
7. Connect to Ductwork
8. Connect Electric
a) Remove the junction box cover (see Figure 5 on
page 11).
b) Remove circular knock-out holes located on back
side of the insert (see Figure 5 on page 11).
c) Connect wiring for blower motor (see blower
instructions beginning on page 11).
d) Ensure all controls are in the OFF position. Plug
electrical cord into grounded outlet.
9. Install Hood Filters and Grease Trays
a) Refer to "Installing Grease Trays, Filter Spacers,
and Filters" on page 28.
10. Test the installation.
a) Test the operation of the blower and the lights.
b) Be sure to check for backdraft. With the blower on
high, close the windows and doors to the area to
ensure that fan does not cause back drafting in any
outlet vent for another appliance.
English 27

Publicité

Table des Matières
loading

Table des Matières