Assembly of the Transition
10" (254 mm)
Duct
1" (25.4 mm)
screw x2
/ "
3
5 16
(84 mm)
4 5/ 16 "
(502 mm)
11¼"
(286 mm)
Figure 2: Transition Dimensions
21¾"
(552 mm)
17½"
(444 mm)
Figure 3: Transition Cutout
1. A minimum height clearance of 10¼" (260 mm) is
needed above the hood for transition mounting.
2. Remove transition from inside of hood. Discard
brackets attaching transition to the inside of hood.
3. Align mounting holes at base of transition with the
mounting holes of the 1/2" (13 mm) flange located at
the top or rear of the hood.
4. Fasten transition to hood using two (2) 1" (25.4 mm)
sheet metal screws included with hood.
5. Seal connection between transition and hood with
aluminum tape. DO NOT use duct tape.
6. Remove tape holding damper closed.
10¼"
(260 mm)
12
13
/
16
(325 mm)
Figure 4: Transition Centerline
English 9
"