Iberspa 43639 Manuel D'utilisation page 28

Masquer les pouces Voir aussi pour 43639:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
circuit, massage and circulation pumps will be automatically switched on for 30 min. if the
water temperature is between 5 and 9ºC and pumps are inactive for more than 60 min.
If the water temperature is less than 5ºC, pumps will be activated until the water
temperature reaches at least 5ºC.
Water temperature (ºC)
AUTO-FILL
The system includes automatic filling through the surge tank. This system ensures that
the spa water has been filtered before reaching the spa.
This system is only active in manual mode.
To use the auto-fill to fill the spa, ensure that the solenoid fill valve is connected to a water
supply and that all valves are opened properly. Switch the system to MANUAL mode (see
5.3.4. to set up in MANUAL mode).
The system will fill the entire hydraulic circuit.
Errors E1 and E11 will appear while the spa is filling for informative purposes. Once the
entire circuit is filled (spa, filter and tank), press the SET button and put the system in
MANUAL mode to delete the error messages.
DAY WATER REPLACEMENT
This system opens the solenoid fill valve in order to replace water once or twice a day for
a maximum of 99 minutes each time the system runs, so that a maximum of 198 minutes
can be programmed daily.
• Press
for 3 seconds when the system is in MANUAL mode and the PARAMETER
SETUP MENU will appear.
• The first parameter, Un (Unit of temperature), will appear on the screen
• Press
3 times and the r n parameter will appear:
o r n = 0 -> system deactivated
o r n = 1 -> only once a day, the solenoid valve will open at 6:00 a.m.
o r n = 2 -> twice a day, the solenoid valve will open at 6:00 a.m. and 6:00 p.m.
• Press
or
Note: The user may not change the times the solenoid valve is opened.
• Press
to confirm and the d3 parameter will appear:
• Press
or
• Press
to confirm.
28
5 - 9
< 5
to change the r n value.
to change and program how long the valve is open (0 to 99 minutes).
Activation time (minutes)
30
Continuous

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

16412ce04015ce05135ce