Parameter
Description
PF
On/Off Filtration Pump
BL
On/Off Blower
P1
On/Off Pump 1
P2
On/Off Pump 2
P3
On/Off Pump 3
DAILY WATER REPLACEMENT FUNCTION
Legislation requires that public use spas guarantee that a percentage of spa water
is replaced daily. The replacement rate will depend on the legislation in force in each
country.
This system opens the solenoid fill valve daily for a certain period of time (which can be
set by the customer according to the diameter and pressure of the fill system).
The water replacement function takes into account the amount of time the solenoid fill
valve is open for maintenance and/or auto-fill functions, subtracting this amount of time
from that programmed by the customer.
The water replacement function will still run even if the circuit is filled to the surge tank's
maximum level.
Manual drainage is required should the circuit require draining due to excess water in the
surge tank.
TEMPERATURE
• Current Spa temperature is shown in the display when the system is in ON mode.
ON / STANDBY button
• Press
or
once the programmed temperature (Set Point) is shown in the display.
• Continue pressing
• When the temperature will be in the desired value stop pressing. The system memorizes
the value automatically.
• Default spa temperature is 36ºC.
• If the power supply is interrupted, the programmed temperature (Set Point) value returns
to the last Set Point programmed.
Parameter
Description
Programmed
SP
temperature
Manual Pumps Activation
Value
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
lights up.
or
the programmed temperature (SP) will go up or down.
Temperature Program
Interval
15-40 (ºC)
59-104 (ºF)
Default value
Involved Function
OFF
Filtration / Backwashing
OFF
OFF
Water massage
OFF
Water massage
OFF
Water massage
Default value
36 (ºC)
97 (ºF)
ENG
Air massage
Involved
Function
Heating
25