Device Information - Dimplex LI 11TES Instructions D'installation Et D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

LI 11TES - LI 16TES

12 Device Information

1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance levels
3
Operating limits
3.1
Heating water flow / return
3.2
Air
4
Flow / sound
4.1
Heating water flow internal pressure differential
Nominal flow according to EN 14511 at A7 / W35-30
Minimum heating water flow
4.2
Sound power level according to EN 12102
device/external
4.3
Sound pressure level at a distance of 1 m indoors
4.4
Heating water flow
with an internal pressure differential of
5
Dimensions, weight and filling quantities
3
5.1
Device dimensions
5.2
Weight of the transportable unit(s) incl. packaging
5.3
Device connections for heating system
5.4
Air duct connection (air intake side)
Air duct connection (air outlet side)
5.5
Refrigerant; total filling weight
5.6
GWP value / CO
equivalent
2
5.7
Refrigeration circuit hermetically sealed
5.8
Lubricant; total filling quantity
5.9
Volume of heating water in device
6
Electrical connection
6.1
Supply voltage / fuse protection
separate infeed:
separate infeed:
combined infeed:
RCD-Type
6.2
Control voltage; fuse protection
6.3
Degree of protection according to EN 60 529
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current
6.7
Nominal power consumption at A7/W35 / max. consumption
(without 2nd heat generator)
6.8
Nominal current at A7/W35 / cos
6.9
Power consumption of compressor protection (per compressor)W
6.10 Power consumption of fan
6.11 Output of electric heating element (2nd heat generator)
7
Complies with the European safety regulations
www.gdts.one
° C
° C
m³/h / Pa
at A7 / W45-40
m³/h / Pa
at A7 / W55-47
m³/h / Pa
m³/h / Pa
dB(A)
2
dB(A)
m³/h / Pa
m³/h / Pa
H x B x T mm
kg
Inches
mm
mm
type / kg
--- / t
type / litres
litres
heat pump
2nd heat generator
heat pump + 2nd heat generator
A
4
kW
A / --
W
kW
452161.66.21 · FD 9912
LI 11TES
Air
Universall
Integrated
Optional (as an accessory)
Indoors
1
1
up to 60
± 2 / from 18
-20 to +35
1.9 / 17400
1.8 / 15500
1.1 / 6100
1.0 / 5100
51 / 53
46
3800 / 0
3200 / 25
1360 x 750 x 850
216
R 1¼"
500 x 500
500 x 500
R410A / 2.3
2088 / 5
yes
Polyolester (POE) / 1.2
3.4
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C20 A
A
1~/N/PE 230 V (50 Hz) / C13 A
IP 21
Soft starter
yes
19
2.4 / 4.1
4.5 / 0.76
--
up to 250
6
5
English
LI 16TES
Air
Universall
Integrated
Optional (as an accessory)
Indoors
1
1
up to 60
± 2 / from 18
-20 to +35
3.1 / 22300
2.9 / 18900
2.0 / 9000
1.4 / 4400
54 / 55
49
5000 / 0
4000 / 25
1570 x 750 x 850
235
R 1¼"
650 x 650
650 x 650
R410A / 3.5
2088 / 7
yes
Polyolester (POE) / 1.9
3.5
3~/PE 400 V (50 Hz) / C16 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C25 A
A
1~/N/PE 230 V (50 Hz) / C13 A
IP 21
Soft starter
yes
28
4.1 / 6.9
7.4 / 0.8
--
up to 300
6
5
EN-13