Riello Condexa 26 KIS Instructions D'installation page 70

Masquer les pouces Voir aussi pour Condexa 26 KIS:
Table des Matières

Publicité

A5
DIGITS
CLIGNOTENT
b-26
NON
DIGITS
CLIGNOTENT
E-30
OUI
CONTRÔLER LA
POMPE OU LE
CIRCUIT
HYDRAULIQUE
NON
DIGITS
CLIGNOTENT
E-33
OUI
CONTRÔLER
SONDE NTC3 OU
CONNEXIONS
NON
SUBSTITUER
VENTILATEUR
OUI
SUBSTITUER
CARTE MCBA
70
NON
DIGITS
CLIGNOTENT
E-31
NON
DIGITS
CLIGNOTENT
OUI
E-32
NON
DIGITS
CLIGNOTENT
E-36
OUI
CONTRÔLER
SONDE NTC1 OU
CONNEXION
LE SIGNAL
TACHO EST
PRESENT SUR LE
CONNECTEUR DU
VENTILATEUR
OUI
SIGNAL TACHO
ENTRE LES TERMINAUX
NON
X2.4 & X2.2 SUR LA
CARTE
MCBA
SUBSTITUER
CÂBLAGE OU
CONNEXIONS
OUI
OUI
CONTRÔLER
SONDE NTC1 OU
CONNEXION
CONTRÔLER
SONDE NTC2 OU
CONNEXIONS
NON
DIGITS
CLIGNOTENT
E-37
OUI
CONTRÔLER
SONDE NTC2 OU
CONNEXIONS
OUI
PARAMÈTRE
OUI
NO. 78
CORRECT
CONTRÔLER
PRESSOSTAT
CONDENSATION
OUI
LE CONNECTEUR
SUBSTITUER
CARTE DE
CONTRÔLE
OUI
CONDENSATION
SUBSTITUER
CÂBLAGE OU
CONNEXIONS
NON
CONDENSATION
SUBSTITUER
PRESSOSTAT
CONDENSATION
CONDENSATION
NON
DIGITS
OUI
CLIGNOTENT
E-38
CONTRÔLER
NON
SONDE NTC3 OU
CONNEXIONS
DIGITS
CLIGNOTENT
NON
E-08
NON
CORRIGER
LE PARAMÈTRE
0 Vac SUR
X2.6 & X2.9
NON
0 Vac SUR
PRESSOSTAT
NON
PRESSOSTAT
OK
OUI
CONTRÔLER
VIDANGE