STEINEL L 605 S Mode D'emploi page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
• Using a voltage, check to make sure
the light is disconnected from the
power supply.
• Make sure power supply remains
interrupted.
Risk of damage to property!
Mixing up connection leads may
produce a short circuit.
• Identify connection leads.
• Re­connect connection leads.
Preparing for installation
• Check all components for damage.
Do not use the product if it is
damaged.
• Select an appropriate site to install
the product.
– Take reach into consideration.
(Fig. 4.1)
– Take reach and motion detection
into consideration. (Fig. 4.2/4.3)
– Vibration­free.
– No obstacles in detection zone.
– Not in explosive atmospheres.
– Not on normally flammable
surfaces.
Mounting procedure
• Check to make sure the power
supply is switched OFF. (Fig. 3.8)
• Unscrew locking screw. (Fig. 4.4)
• Disconnect light from the wall mount
by pressing the clip. (Fig. 4.4)
• Mark drill holes. (Fig. 4.5)
• Drill holes (Ø 6 mm) and fit wall plugs.
(Fig. 4.6)
• Firmly screw wall mount into place.
(Fig. 4.7)
• Connect conductors as shown in the
wiring diagram. (Fig. 4.8/3.8)
• Fit light on the wall mount. (Fig. 4.9)
• Tighten locking screw. (Fig. 4.9)
• Switch ON power supply. (Fig. 4.9)
5. Use L 605 S
Factory settings
– Time setting: 5 seconds
– Twilight setting:
daylight mode
– Programme setting:
Programme 1
Time setting (Fig. 5.1)
The time (stay­ON time) can be set
to any period from approx. 5 seconds to
a maximum of 15 minutes. Every move­
ment detected re­activates the light.
Twilight setting (Fig. 5.1)
The brightness response threshold
(twilight) can be infinitely varied from
approx. 10 to 2000 lux.
= daylight mode (depending on
ambient light level)
= night­time operation (approx.
10 lux)
Programme setting (programme 1-4)
(Fig. 5.1)
– With soft light start, light output is
slowly increased to 100% when the
light is switched ON, slowly reduced
when the light is switched OFF.
– Night light is continuous night­time
illumination at approx. 10% light
output. Light is switched to 100%
output when movement is identified
in the detection zone. The light then
switches back to night light.
Programme 1
off
Standard programme
– Soft light start.
– No night light.
Programme 2
User-friendly economy
1/2
programme
– Soft light start.
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

L 605

Table des Matières